{"product_id":"detector-personal-de-gas-h2s-portable-gas-detector-iecex-atex-ip68-coal-mining-gas-detector","title":"Detector Personal De Gas H2S Portable Gas Detector","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003etype : \u003c\/strong\u003e Detector Personal De Gas H2S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003emodel number : \u003c\/strong\u003e MiniMeta\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ebrand name : \u003c\/strong\u003e Safegas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eplace of origin : \u003c\/strong\u003e Guangdong, China\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecustomized support : \u003c\/strong\u003e OEM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ewarranty : \u003c\/strong\u003e 2 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct : \u003c\/strong\u003e Detector Personal De Gas H2S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor type : \u003c\/strong\u003e Eletectrochemical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Detected : \u003c\/strong\u003e CO H2S O2 NH3 SO2, etc different gases\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution : \u003c\/strong\u003e 1ppm, 0.1ppm, 0.1%VOL, etc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSampling method : \u003c\/strong\u003e Diffusion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse time : \u003c\/strong\u003e ≤ 30s (T90)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay : \u003c\/strong\u003e Gas name , concentration unit, measured value , electricity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm type : \u003c\/strong\u003e Low alarm, High alarm, STEL, TWA, low battery\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExplosion-proof grade : \u003c\/strong\u003e Ex ia II CT 4 Ga\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection class : \u003c\/strong\u003e IP68\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"J_module\"\u003e\n\u003cdiv id=\"ali-anchor-AliMagic-xlm4zl\" class=\"magic-15\"\u003eTechnical Specifications\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"J_module\"\u003e\n\u003cdiv class=\"ife-detail-decorate-table\"\u003e\n\u003ctable class=\"all magic-16\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-17\"\u003e\u003cb\u003e\u003cspan style=\"font-family: Arial;\"\u003eDetected gas:\u003c\/span\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-18\"\u003eH2S, CO, O2, SO2, NH3, etc different single gases. According to customers' requirements.\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-17\"\u003e\u003cb\u003e\u003cspan style=\"font-family: Arial;\"\u003eDetection principle:\u003c\/span\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-18\"\u003e\u003cspan style=\"font-family: Arial;\"\u003eElectrochemical, according to gas, sensor and measure range.\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-17\"\u003e\u003cb\u003e\u003cspan style=\"font-family: Arial;\"\u003eMeasure range:\u003c\/span\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-18\"\u003eCarbon Monoxide(CO): 0-500ppm\/1000ppm\/2000ppm, Hydrogen Sulfide(H2S): 0-100ppm\/200ppm, Oxygen(O2): 0-25%VOL\/30%VOL, according to customer's requirements.\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-17\"\u003e\u003cb\u003e\u003cspan style=\"font-family: Arial;\"\u003eResolution:\u003c\/span\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-18\"\u003eCarbon Monoxide(CO): 1ppm, Hydrogen Sulfide(H2S): 0.01ppm, Oxygen(O2): 0.01%VOL, according to sensor and measure ranges.\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-17\"\u003e\u003cb\u003e\u003cspan style=\"font-family: Arial;\"\u003eAccuracy:\u003c\/span\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-18\"\u003e\u003cspan style=\"font-family: Arial;\"\u003e≤±3%F.S. (higher precision can be customized)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-17\"\u003e\u003cb\u003e\u003cspan style=\"font-family: Arial;\"\u003eResponse time:\u003c\/span\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-18\"\u003e\u003cspan style=\"font-family: Arial;\"\u003e≤30 seconds (T90)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-17\"\u003e\u003cb\u003e\u003cspan style=\"font-family: Arial;\"\u003ePower Model:\u003c\/span\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-18\"\u003e\u003cspan style=\"font-family: Arial;\"\u003e3.6V dry battery (non-removable and rechargeable)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-17\"\u003e\u003cb\u003e\u003cspan style=\"font-family: Arial;\"\u003eDisplay:\u003c\/span\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-18\"\u003e\u003cspan style=\"font-family: Arial;\"\u003eGas name, concentration unit, measured value, electricity\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-17\"\u003e\u003cb\u003e\u003cspan style=\"font-family: Arial;\"\u003eConcentration unit:\u003c\/span\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-18\"\u003e\u003cspan style=\"font-family: Arial;\"\u003eppm, mg\/m3, %VOL, etc\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-17\"\u003e\u003cb\u003e\u003cspan style=\"font-family: Arial;\"\u003eAlarm mode:\u003c\/span\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-18\"\u003e\u003cspan style=\"font-family: Arial;\"\u003eSound, light, vibration alarm, high and low alarm values can be set by yourself.\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-17\"\u003e\u003cb\u003e\u003cspan style=\"font-family: Arial;\"\u003eExplosion-proof grade:\u003c\/span\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-18\"\u003e\u003cspan style=\"font-family: Arial;\"\u003eIECEX ATEX(from TUV)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-17\"\u003e\u003cb\u003e\u003cspan style=\"font-family: Arial;\"\u003eProtection Class:\u003c\/span\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-18\"\u003e\u003cspan style=\"font-family: Arial;\"\u003eIP68\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-17\"\u003e\u003cb\u003e\u003cspan style=\"font-family: Arial;\"\u003eExecutive standards:\u003c\/span\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-18\"\u003eGB 12358-2006, GB 3836.1-2010, GB 3836.4-2010, JJF1421-2013, JJF1363-2019, JJF1364-2012, JJG 365-2008, IEC 60079-0-2017, IEC\u003cbr\u003e60079-11-2\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-17\"\u003e\u003cb\u003e\u003cspan style=\"font-family: Arial;\"\u003eWorking temperature:\u003c\/span\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-18\"\u003e\u003cspan style=\"font-family: Arial;\"\u003e-20℃～55℃\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-17\"\u003e\u003cb\u003eWorking humidity:\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-18\"\u003e0-95%RH (non-condensing\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-17\"\u003e\u003cb\u003eWorking air pressure:\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-18\"\u003e86~106kpa\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-17\"\u003e\u003cb\u003eLanguage:\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-18\"\u003eEnglish\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-17\"\u003e\u003cb\u003eDimensions:\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-18\"\u003e90*60*33mm (length*width*thickness)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-17\"\u003e\u003cb\u003eWeight:\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-18\"\u003e125g\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Utility Electrical Co., Ltd.","offers":[{"title":"3%FS \/ H2S: 0-100ppm","offer_id":49373435429108,"sku":"1600523616491","price":403.65,"currency_code":"NZD","in_stock":true},{"title":"3%FS \/ CO: 0-1000ppm","offer_id":49373435953396,"sku":"1600523616491","price":403.65,"currency_code":"NZD","in_stock":true},{"title":"3%FS \/ O2: 0-30%VOL","offer_id":49373435986164,"sku":"1600523616491","price":464.6,"currency_code":"NZD","in_stock":true},{"title":"3%FS \/ SO2: 0-100ppm","offer_id":49373436018932,"sku":"1600523616491","price":1008.55,"currency_code":"NZD","in_stock":true},{"title":"3%FS \/ NH3: 0-100ppm","offer_id":49373436051700,"sku":"1600523616491","price":1008.55,"currency_code":"NZD","in_stock":true},{"title":"3%FS \/ CL2: 0-100ppm","offer_id":49373436084468,"sku":"1600523616491","price":1008.55,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0746\/1027\/8644\/files\/H3cbe6dec9c9143fca6402c5d54f28a866.webp?v=1789171372","url":"https:\/\/www.controls-instrument.co.nz\/products\/detector-personal-de-gas-h2s-portable-gas-detector-iecex-atex-ip68-coal-mining-gas-detector","provider":"Controls-Instrument - Precision Sourced - Industrially Proven","version":"1.0","type":"link"}