{"product_id":"2865366-macx-mcr-ex-sl-rpssi-2i-ex-i-measuring-input-signal-conditioner-transducer-power-supply","title":"2865366 Signal Conditioner Transducer Power Supply","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number : \u003c\/strong\u003e MINI MCR-BL-I-I\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand Name : \u003c\/strong\u003e Phoenixcontact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlace of Origin : \u003c\/strong\u003e Germany\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct name : \u003c\/strong\u003e Ex I Measuring Input Signal Conditioner Transducer Power Supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type : \u003c\/strong\u003e Repeater power supplies\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew thread : \u003c\/strong\u003e M3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStripping length : \u003c\/strong\u003e 7mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor cross section AWG : \u003c\/strong\u003e 24 ... 14\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution degree : \u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStep response : \u003c\/strong\u003e 1.3 ms (for jump 4 mA ... 20 mA, typical)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower consumption : \u003c\/strong\u003e ≤ 1.8 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin : \u003c\/strong\u003e DE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of inputs : \u003c\/strong\u003e 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eProducts Description\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch3\u003e\u003cspan\u003e\u003cspan\u003eProduct advantages\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan\u003e\u003cspan\u003e * 0\/4 mA ... 20 mA input, intrinsically safe, [Ex ia], powered and not powered \u003cbr\u003e* Measuring transducer supply voltage \u0026gt; 16 V \u003cbr\u003e* Two electrically isolated 0\/4 mA ... 20 mA (active) outputs \u003cbr\u003e* Bidirectional HART transmission (both outputs) \u003cbr\u003e* Error indication according to NAMUR NE 43 \u003cbr\u003e* SIL 2 according to IEC\/EN 61508 \u003cbr\u003e* Safe electrical isolation between input, outputs, and supply \u003cbr\u003e* Power supply possible via DIN rail connector \u003cbr\u003e* Installation in zone 2 permitted \u003cbr\u003e* Plug-in connection terminal blocks, screw connection technology, with integrated sockets for HART communicators \u003cbr\u003e* Housing width: 12.5 mm \u003cbr\u003e* Minimal power dissipation \u003cbr\u003e* High transmission accuracy\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eProduct Paramenters\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eProduct name\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e2865366 Ex I Measuring Input Signal Conditioner Transducer Power Supply\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eItem number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e2865366\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eScrew thread\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003eM3\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eGTIN\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e4046356160384\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eProduct family\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003eMACX Analog\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ePower consumption\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e≤ 1.8 W\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eDegree of protection\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003eIP20 (not assessed by UL)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Nanjing Youhuo Electric Co., Ltd.","offers":[{"title":"Default Title","offer_id":49387748065524,"sku":"1601157005706","price":949.9,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0746\/1027\/8644\/files\/Hcb96650d827046a7bd93de030f3c7104m.webp?v=1789366092","url":"https:\/\/www.controls-instrument.co.nz\/products\/2865366-macx-mcr-ex-sl-rpssi-2i-ex-i-measuring-input-signal-conditioner-transducer-power-supply","provider":"Controls-Instrument - Precision Sourced - Industrially Proven","version":"1.0","type":"link"}